Fresh install mini split

Fresh install mini split





  • Fresh install mini split


    I recently installed a mini split in my garage. I ran the lines and electrical and now im vacuuming down the lines. I’ve run the pump for 15-20 minutes twice and maintained -30inhg for the entire time. Then I close the valve shut the pump off and wait 30 minutes to and hours. After an hour I noticed that its risen to -20inhg. Is this normal for a mini split or do I have a leak somewhere I missed. I don’t want to release the refrigerant if this is a leak. Can any help? Thanks.







  • Microns not inches…..
    Anything less is a waste.
    You’ve probably got a leak and are sucking vapor in…


















  • Originally Posted by Cowguy27
    View Post

    I recently installed a mini split in my garage. I ran the lines and electrical and now im vacuuming down the lines. I’ve run the pump for 15-20 minutes twice and maintained -30inhg for the entire time. Then I close the valve shut the pump off and wait 30 minutes to and hours. After an hour I noticed that its risen to -20inhg. Is this normal for a mini split or do I have a leak somewhere I missed. I don’t want to release the refrigerant if this is a leak. Can any help? Thanks.

    No micron gauge

    Good luck.

    Hope you saved a lot with that on line purchase!



















  • You seem to have skipped the pressure leak test. That’s one of the most important steps of all.

    “I haven’t failed. I’ve just found 10,000 ways that won’t work.” – Thomas Edison

    “It’s not whether you get knocked down, it’s whether you get up.” – Vince Lombardi

    “In this house we obey the laws of thermodynamics” – Homer Simpson

    Local 486 Instructor & Service Technician






  • Fresh install mini split Originally Posted by rider77
    View Post

    You seem to have skipped the pressure leak test. That’s one of the most important steps of all.

    I’m sure a lot of other steps were skipped!







  • Yes there is likely a leak. Standard practice is to pull a vacuum to less than 500 microns and it does not rise above 1000. If you hold under 1000 for 10 min the system is usually said to be leak free.

    Best way to find the leak is pump dry nitrogen into the system to whatever the manual states. Some say 600 psi some say other number. Once there is pressure you use leak search bubble spray and spray in on joints. If it blows/forms bubbles that is where the leak is.

    Sent from my iPhone using Tapatalk







  • What pump and gauges are you using?

    Sent from my iPhone using Tapatalk