    Why doesn’t a 2 story foyer or family room count as double the sq feet, as there is double the air to be cooled?

    I have almost 500 “extra” square feet of space as I have a large 2 story family room and 2 story foyer. The heat from my first floor rises upstairs and makes the upstairs very hot in the summer.







  • Because square footage or cubic footage has absolutely nothing to do with cooling/heating requirements.

    “Is this before or after you fired the parts cannon at it?” – senior tech

    I’m tired of these mediocre “semi flammable” refrigerants. If we’re going to do it let’s do it right.

    Unless we change direction we are likely to end up where we are going.

    “It’s not new, it’s better than new!” Maru.



















  • Sounds like you have a problem with air distribution likely due to bad duct design.

    “Is this before or after you fired the parts cannon at it?” – senior tech

    I’m tired of these mediocre “semi flammable” refrigerants. If we’re going to do it let’s do it right.

    Unless we change direction we are likely to end up where we are going.

    “It’s not new, it’s better than new!” Maru.







  • It sounds like the area wasn’t properly figured & it has nothing to do with how the sq. ft. of the area was or was not counted.
    What counts most is the area exposed to the outside or unconditioned air & glass. That needs to be accounted for when doing a load calculation.
    If you have a 23×23 room with three exterior walls & an 8 ft. ceiling it would be 552 sq. ft. of outside wall to be calculated.
    That same room with 16 ft. ceiling would now have double(1104 sq. ft) of exterior wall to be calculated. Then the glass, floors ,ceiling area & infiltration has to be accounted for.

    Gary
    ———–
    http://www.oceanhvac.com
    The best things in life are free but not everyone is willing to pay the price.


















  • Originally Posted by jersey2022
    View Post
    Why doesn’t a 2 story foyer or family room count as double the sq feet, as there is double the air to be cooled?

    I have almost 500 “extra” square feet of space as I have a large 2 story family room and 2 story foyer. The heat from my first floor rises upstairs and makes the upstairs very hot in the summer.

    Buildng Thermal Envelope. The bigger picture … https://www.youtube.com/watch?v=7yhGDm1Rpg4

    Designer Dan __ It’s Not Rocket Science, But It is SCIENCE with Some Art. _ _ KEEP IT SIMPLE & SINCERE ___ __ www.mysimplifiedhvac.com ___ __ Define the Building Envelope & Perform a Detailed Load Calc: It’s ALL About Windows & Make-up Air Requirements. Know Your Equipment Capabilities